Structural Floor I
Home ] Up ]

 

Home
Structural Floor I
Structural Floor II

 

 

RETROFITTING STRUCTURAL STEEL FLOOR SYSTEMS

EXPANSIVE CLAY SOILS (BENTONITE) UNDER SLABS ON GRADE CAN RESULT IN SERIOUS STRUCTURAL DAMAGE.  THE SOLUTION IS THE INSTALLATION OF A STRUCTURAL FLOOR SYSTEM TO REPLACE THE ORIGINAL SLAB ON GRADE.

StrucFloor 1.JPG (1338734 bytes)    StrucFloor 2.JPG (1415626 bytes)

PRIOR TO REMOVAL OF THE ORIGINAL SLAB, THE CONCRETE BASEMENT WALLS MUST BE SHORED AGAINST MOVEMENT

 

strucFloor 3.JPG (1444798 bytes)    StrucFloor 4.JPG (1471961 bytes)    StrucFloor 5.JPG (1472727 bytes)

SLAB IS REMOVED AND THE LOWER LEVEL EXCAVATED TO 3 FEET BELOW ORIGINAL GRADE.  EXPOSURE OF CONSTRUCTION DEFECTS ARE REVEALED.  NOTE SPECIAL SHORING REQUIRED DUE TO DEFECTIVE COLUMN AND PIER ALIGNMENT AND SUBSEQUENT DETERIORATION.  THESE DEFECTS WERE DISCOVERED JUST PRIOR TO INITIATION OF COLLAPSE OF THE MAIN LEVEL INTO THE BASEMENT DUE TO FAILURE OF THESE TWO COLUMNS.

 

StrucFloor 6.JPG (1432512 bytes)

ALL MECHANICAL EQUIPMENT REMAINS IN PLACE AND IS SUSPENDED FROM THE FIRST FLOOR STRUCTURE

 

StrucFloor 7.JPG (1352328 bytes)    StrucFloor 8.JPG (1293935 bytes)

INSTALLATION OF WIDE FLANGE STRUCTURAL MEMBERS, PLYWOOD DECK, FLOORING, AND FINISH TREATMENTS INCLUDING CRAWL SPACE VENTILATION SYSTEM CONTROLLED BY HUMIDITY SENSORS